Chad, Central African Republic, Cameroon, Equatorial Guinea, Gabon, The Republic of Congo , The Democratic Republic of the Congo, The Democratic Republic of Sao Tome and Principe, Belarus, Estonia, Kosovo, Latvia, Lithuania, Moldova, Russia, Ukraine, Algeria, Egypt, Libya, Morocco, Sudan, Tunisia, Brunei, Cambodia, East Timor, Indonesia, Laos, Myanmar, Malaysia, Philippines, Singapore, Thailand, Vietnam, Angola, Botswana, Comoros, Lesotho, Malawi, Mozambique, Madagascar, Mauritius, Namibia, South Africa, Swaziland, Saint Helena, Zambia, Zimbabwe, Burkina Faso, Benin, Cape Verde, Côte d'Ivoire, Gambia, Guinea, Guinea-Bissau, Ghana, Liberia, Mauritania, Mali, Niger, Nigeria, Senegal, Sierra Leone, Togo, Western Sahara
Chad, Central African Republic, Cameroon, Equatorial Guinea, Gabon, The Republic of Congo , The Democratic Republic of the Congo, The Democratic Republic of Sao Tome and Principe, Belarus, Estonia, Kosovo, Latvia, Lithuania, Moldova, Russia, Ukraine, Algeria, Egypt, Libya, Morocco, Sudan, Tunisia, Brunei, Cambodia, East Timor, Indonesia, Laos, Myanmar, Malaysia, Philippines, Singapore, Thailand, Vietnam, Angola, Botswana, Comoros, Lesotho, Malawi, Mozambique, Madagascar, Mauritius, Namibia, South Africa, Swaziland, Saint Helena, Zambia, Zimbabwe, Burkina Faso, Benin, Cape Verde, Côte d'Ivoire, Gambia, Guinea, Guinea-Bissau, Ghana, Liberia, Mauritania, Mali, Niger, Nigeria, Senegal, Sierra Leone, Togo, Western SaharaEssential details
Supply Ability
Packaging & delivery
Quantity(pieces) | 1 - 2 | 3 - 50 | 51 - 200 | >200 |
Lead time (days) | 16 | 30 | 45 | To be negotiated |
iTeaQ Power High frequency online 500kva ups with 10pcs 50kw modules for Security
50K module
ECOplus 50-600kVA Modular UPS (50k module)
Introduction:
ECOplus 50-600kVA is a new generation three-in-three-out modular UPS launched by our company. The products adopt digital control, modular design and N+X parallel redundancy technology, which integrates the most advanced technical achievements in the field of power electronics and automatic control. It is benchmarking product in the modular UPS field. The capacity covers all power sections between 50kVA and 600kVA, which is convenient for users to configure flexibly and gradually invest. It can be 4 parallel to 2400kVA.
Scenarios:
Large and medium data centers, server rooms.
Financial centers, government, enterprise IT rooms, medical
education and other mission-critical applications.
Features:
1.Centralized bypass, centralized control, modular design
2.Online double conversion and three level technology
3.DSP digital control technology
4.Wide input voltage range
5.Output power factor 1
6.High power density with size 440mm*620mm*3U
7.Cold start (battery start up)
8.ECO mode operation
9.Intelligent battery management
10.N+X redundancy
11.Communications: RS485/Relay card/USB/SNMP option
12.Optional emergency power off (EPO) function
13.Compatible with lithium battery applications
Benefits:
1.Modular design, improves maintainability and reliability
2.ECO mode operation for energy saving
3.Cold start for easy operation
4.Communications for network management and remote monitoring
5.N+X redundancy, expanding as required, saves initial investment
50K specifications
Model | ECOplus200-50 | ECOplus300-50 | ECOplus400-50 | ECOplus500-50 | ECOplus600-50 | ||
Capacity | Cabinet | 50~200kW | 50~300kW | 50~400kW | 50~500kW | 50~600kW | |
Module | 50kW | ||||||
Max. Module Number | 4 | 6 | 8 | 10 | 12 | ||
Input | Phase | 3 Phase 4 Wires and Ground | |||||
Rated Voltage | 380/400/415Vac | ||||||
Voltage Range | 138~485Vac | ||||||
Frequency Range | 40Hz-70Hz | ||||||
Power Factor | ≥0.99 | ||||||
Current THDi | ≤3%(100% linear load) | ||||||
Bypass Voltage Range | Max.voltage: 220V:+25 %( optional +10%, +15%, +20%); 230V:+20 %( optional +10%, +15%); 240V:+15 %( optional +10%) | ||||||
Min. voltage:-45 %( optional -10%, -20%,-30%) | |||||||
Frequency protection range: ±10% | |||||||
Power Walking In | Yes | ||||||
Bypass back irrigation | Bypass back irrigation | ||||||
Generator access | Yes | ||||||
Output | Phase | 3 Phase 4 Wires and Ground | |||||
Rated Voltage | 380/400/415Vac | ||||||
Power Factor | 1 | ||||||
Voltage Regulation | ±1% | ||||||
Frequency | Utility Mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional) | |||||
Battery Mode | (50/60±0.1%)Hz | ||||||
Crest Factor | 3:1 | ||||||
THD | ≤2% with linear load, ≤4% with non linear load | ||||||
Effieiency | 96% | ||||||
Overload | ≤ 110%, to bypass after 60 min; ≤ 125%, to bypass after 10 min; ≤ 150%, to bypass after 1 min | ||||||
Battery | Voltage | ±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional) | |||||
Module charge current | Max 20A | ||||||
Transfer Time | Utility to Battery : 0ms; Utility to bypass: 0ms | ||||||
Protection | Alarm | overload, utility abnormal, UPS fault, battery low, etc | |||||
Protection | short circuit, overload, over temperature, battery low, fan fault alarm | ||||||
Communication Interface | CAN, RS485, FE, LBS, Parallel card, Relay card, SNMP card(optional) | ||||||
Environment | Operating Temperature | 0℃~40℃ | |||||
Storage Temperature | -25℃~55℃ | ||||||
Humidity | 0~95% non condensing | ||||||
Altitude | < 1500m | ||||||
Noise level | <65dB | <68dB | <70dB | ||||
Other | Cabinet Dimensions(W*D*H)mm | 600*850*2000 | 1200*850*2000 | ||||
Module Dimensions(W*D*H)mm | 440*620*131 | ||||||
Cabinet Weight (Kg) | 262 | 272 | 360 | 380 | 400 | ||
Module Weight (Kg) | 33 | ||||||
Standards | EN62040-1, EN62040-2 |